Pressure and Sampling Adapters
The versatile Jet Test QD® has many uses other than those shown on Bulletin 14. This permanently installed, impact resistant, quick disconnect is unique because only its stainless steel hex is exposed.
Standard Jet Test QD®s require the long actuator. Refueling nozzles such as those made by Avery Hardoll (now known as Meggitt) use a shorter actuator because the long version would interfere with the nozzle strainer. Short versions have suffix S or AH in the model number.
See below for components and variations of these two assemblies.
Selecting the Correct Actuator (Connector) for GTP-423 and GTP-451 Shut-off Valves
GTP-423
(standard model) has GTP-1173 actuator for connection to GTP-235 Jet Test QD as shown above
GTP-423-1
has GTP-722-2 commercial standard actuator
GTP-423-2
has GTP-1175A short actuator for connection to AH and S Jet Test QDs
GTP-423-3
has GTP-1171D actuator for connection to Shell fittings
GTP-423-4
has GTP-1171C actuator for connection to Air NP/Thermal Controls fittings
GTP-451
(standard model) has GTP-235-2 actuator for connection to GTP-235 Jet Test QD as shown above
GTP-451-1
has HN-4 adapter and GTP-722 commercial standard actuator
GTP-451-2
has GTP-235AH actuator for connection to AH and S Jet Test QDs
GTP-451-3
has GTP-1171D actuator and RHN4-2 adapter for connection to Shell fittings
GTP-451-4
has GTP-1171C actuator and RHN4-2 adapter for connection to Air NP/Thermal Controls fittings